ERGOVENT LINEO PRO
Linear Frameless Gypsum Diffuser


LINEO PRO SINGLE 75 / 90 - 1 Slot
The LINEO-PRO SINGLE 1 SLOT is a frameless linear slot diffuser fixed to the concrete ceiling before gypsum framing. It comes in a fixed length, does not connect to further segments, and suits vertical or horizontal installation. Made to order. The lead time is confirmed on your quote.
Technical Features
Application: supply and extraction
Connection sizes: 2.95 in (75 mm) / 3.54 in (90 mm)
Air volume: 47.1 to 70.6 CFM (80 to 120 m³/h)
Slot: 39.37 x 0.79 in (1000 x 20 mm), fixed length
Minimum installation height: 6.30 in (160 mm)
Installation width between profiles: 5.31 in (135 mm)
Fixed to the concrete ceiling before gypsum board framing
Suitable for vertical or horizontal installation
External adjustable balancing damper
Key Benefits
Fixes to the structural ceiling ahead of framing, setting the slot position before the board goes up
Plastered and painted to match the surrounding surface, so only the slot remains on the finished face
Damper is reached from outside, so airflow can be set after finishing
Mounts vertically or horizontally without modification
iF Design Award winner










ERGOVENT LINEO PRO
Linear Frameless Gypsum Diffuser


LINEO PRO SINGLE 75 / 90 - 1 Slot
The LINEO-PRO SINGLE 1 SLOT is a frameless linear slot diffuser fixed to the concrete ceiling before gypsum framing. It comes in a fixed length, does not connect to further segments, and suits vertical or horizontal installation. Made to order. The lead time is confirmed on your quote.
Technical Features
Application: supply and extraction
Connection sizes: 2.95 in (75 mm) / 3.54 in (90 mm)
Air volume: 47.1 to 70.6 CFM (80 to 120 m³/h)
Slot: 39.37 x 0.79 in (1000 x 20 mm), fixed length
Minimum installation height: 6.30 in (160 mm)
Installation width between profiles: 5.31 in (135 mm)
Fixed to the concrete ceiling before gypsum board framing
Suitable for vertical or horizontal installation
External adjustable balancing damper
Key Benefits
Fixes to the structural ceiling ahead of framing, setting the slot position before the board goes up
Plastered and painted to match the surrounding surface, so only the slot remains on the finished face
Damper is reached from outside, so airflow can be set after finishing
Mounts vertically or horizontally without modification
iF Design Award winner